GESTRA BK45 PDF

(Bimetallic) Regulator PN 40 – PN BK 45, BK DN 15, 20, • Robust regulator for roughest operating conditions (unaffected by waterhammer and frost ). Features and Benefits. • Forged steel body and cover. • Pressure assisted fail- open design. • Factory-preset bimetallic regulator with integral staged nozzle. BK BK 45U. BK Installation Instructions Steam Traps BK 45, BK 45U, BK GESTRA Steam Systems. EN. English.

Author: Zuk Mazuran
Country: Gabon
Language: English (Spanish)
Genre: Software
Published (Last): 15 December 2018
Pages: 324
PDF File Size: 18.40 Mb
ePub File Size: 7.97 Mb
ISBN: 323-9-89538-872-5
Downloads: 38621
Price: Free* [*Free Regsitration Required]
Uploader: Godal

Thermostatic steam traps BK 45/46

Acting against this thermal process is the operating pressure and pressure that gesttra up in the chamber of the stage nozzle due to flash steam thermodynamic process. Robust steam traps for condensate removal from heating processes with small load fluctuations.

In steam traps with GESTRA Thermovit regulators, the opening and closing process is controlled by the interaction of bimetallic plates and a stage nozzle. Especially recommended for use in:.

Bimetallic Steam Trap BK45, Steam Traps

Therefore, the column of these plates consists of a spring with a characteristic that is adapted to the valve force, which changes under pressure. Immediately below saturation temperature boiling pointthe duo stainless steel plates are deflected to such an extent that the orifice is almost completely closed.

  3M 700R PDF

This state of equilibrium between the temperature-induced closing and pressure-induced opening forces determines the outlet cross section. It is precisely this principle that makes steam traps from the BK series gestrw responsive, very efficient and extremely resistant. The operating pressure acts in the direction of opening, so that the valve is opened fully.

Just below saturation temperature, the bimetallic plates are deflected to such an extent that the orifice is almost closed.

Cold condensate and air are discharged.

BK 45/46 – Gestra

Use Robust steam traps for condensate removal from heating processes with small load fluctuations. Method of Operation The steam trap is fully open when the system starts up.

Especially recommended for use in: Thermostatic steam traps for removing condensate from steam or for venting steam pipes.

Saturated steam pipes Superheated steam pipes Trace heaters Air heaters Thanks to automatic venting, steam traps from the BK series are also ideal for use as air vents. Advantages Extremely gestta start-up performance No loss of steam Suitable for differential pressure up to bar Able to cope with the harshest operating conditions Any installation position — in horizontal or vertical pipes Inner parts made of corrosion-resistant stainless steel Can be serviced without removing the body from the pipe Metal base bushing provides the seal between the body and bimetallic regulator Stage nozzle for non-return valve action Wear-resistant.

  ECHINODORUS MACROPHYLLUS PDF

This way, thermal and spring properties are coordinated in such a way that the festra and closing temperatures are always just a few degrees below boiling point. Be the first to review! As the temperature of the condensate rises, the duo stainless steel plates deflect and pull the stage nozzle in the closing direction.

GESTRA – Flowserve Corporation

As the temperature of the condensate rises, the bimetallic plates deflect and pull the stage nozzle in the closing direction. When the system starts up and on the formation of cold condensate and air, the duo stainless steel plates lie flat.

However, the temperature-induced deflection of the duo stainless steel plates is not sufficient to generate the required force to counter the valve force acting on the nozzle bj45 in the opening direction throughout the entire operating range.

The opening and closing process is controlled by the interaction of the stage nozzle and the temperature sensor, which consists of duo stainless steel plates. The pressure in the stage nozzle chamber therefore drops and, as the amount of flash steam declines, dissipates altogether.